FF, FT & RC Hot Surface Igniters |
 |
The Surface IgniterTM family of hot surface igniters is the latest refinement of the product originally produced in 1969. Many improvements have been made since then and the result is, we believe, an igniter with a combination of...
- longer useable life (reduced aging),
- greater physical strength,
- lower power consumption,
- superior gas lighting ability,
...than any other igniter on the market today.
Increased life and strength result from our unique reaction bonding process which produces a higher density silicon carbide. This higher density reduces internal oxidation (a cause of aging) and increases structural integrity. Surface IgnitersTM draw less current and light gas at lower
temperatures than competitive products due to the efficient double helix design.
The FF, FT and RC families of reaction-bonded silicon
carbide igniters offer unique ceramic bushing styles to meet
the requirements of "hard-to-fit" applications. The "low-power"
specification of the products make them valuable for use in
applications where power conservation is important. These
products have been successfully employed for "sealed" as
well as atmospheric applications.
|
|
Specifications |
|---|
| Igniter Material: | Reaction Bonded Silicon Carbide |
|---|
| Bushing Material: | Steatite/Cordierite |
|---|
| Temperatures: |
|---|
| @ 98 Volts | 2000º F Minimum |
|---|
| @ 115 Volts | 2300º F nominal |
|---|
| @ 132 Volts | 2700º F maximum |
|---|
| Steady State Current: |
|---|
| @ 98 Volts | 2.30 Amps minimum |
|---|
| @ 115 Volts | 2.50-3.00 Amps |
|---|
| @ 132 Volts | 3.30 Amps maximum |
|---|
Time to Reach Temperature 1800º F | 6-60 seconds. Customer can specify maximum time response from between 17 seconds and 60 seconds @ 115 Volts. |
|---|
Lead Wires (length per customer requests) | UL3122 200º C UL5167 250º C UL5128 450º C |
|---|
| Terminations | Industry standard types avail. |
|---|
| Major Applications | HVAC Sealed and unsealed units |
|---|
| Agency Certifications | American Gas Association Canadian Gas Association |
|---|
|
Townline HVAC 6094 Townline Rd. Lockport, New York 14094 Telephone: (716) 628-1973 Fax: (716) 731-4129 gsiuta@townline-hvac.com |
|